DGJ Generators



Dayliff DGJ Perkins powered generators are robust, high quality units designed for continuous duty in a wide range of power supply applications. All sets offer the following features:-


• Powered by dependable and efficient Perkins (UK,USA) water cooled diesel engines.
• Close coupled at 1500rpm to a brushless single bearing MECC ALTE (UK) or LEROY SOMER alternator with solid state AVR regulation.
• Base frame mounted on anti-vibration mounts and including a high capacity base mounted fuel tank for extended operation time.
• Powder coated sound and weather proof canopies with residential silencer for extremely low noise operation. (80dBA @3m)
• Integral DSE digital control module that provides selectable readout of electrical voltage, phase current, output frequency and battery voltage and engine speed, hours run, oil pressure and coolant temperature. Remote monitoring is available as an option.
• Automatic shut down protection in the event of low engine oil pressure, high engine temperature and over and under speed with warning indicators provided for each condition.
• Digital automatic mains failure provision for starting the generator. An additional automatic transfer switch is also required for mains/generator power transfer.


Dayliff Perkins diesel generators are reliable economical and high specification products that are the ideal solution for all continuous duty and standby power generating requirements.

 

 
TECHNICAL DATA
Generator Model DGPJ07 DGPJ12 DGPJ16 DGJP24 DGJP36 DGJP48 DGJP64 DGJP80 DGJP108 DGJP120 DGJP144 DGJP160 DGJP200 DGJP240 DGJP320 DGJP400 DGJP600 DGJP800
Prime/Standby Power Output kVA 9/10 15/16.5 20/22 30/33 45/50 60/66 80/88 100/110 135/150 150/165 180/200 200/220 250/275 300/330 400/450 500/550 750/825 1000/1100
kW 7/8 12/13.2 16/18 24/26 36/40 48/52.8 64/70.4 80/88 108/120 120/132 144/160 160/176 200/220 240/264 320/360  400/440  600/660  800/880 
Engine Data Perkins Model 403A11G1 403A15G2 404A22G1 1103A33G3 1103A33TG1 1103A33TG2 1104A44TG2 1104C44TAG2 1106A70TG1 1106A70TAG2 1106A70TAG3 1106A70TAG4 1206A-E70TTAG2 16060A-E93TAG5 2206A-E13TAG3 2506A-E15TAG2 4006-23TAG2A 4008-TAG2A
Rated Power @ 1500rpm (kW) 9 14 19 29 42 55 73 94 123 136 162 179 236 281 368 451 658 900
Aspiration Natural Turbocharged
No. of cylinders 3 3 4 3 4 6
Displacement (L) 1.1 1.5 2.2 3.3 4.4 7.0 8.8  12.5 15.2 22.9  30.6 
Fuel Consumptions (litres/hr) 75% load 2 3.1 4 5 8 10 14 17 23 25 32 35 42 48 62 76  122 160 
100% load 3   5.3 7 11 14 19 236 30 33 42 46 56 65 81  100  161 213
Fuel Tank Size (litres) 51 85 110 260 460 505 538  680 N/A  
Alternator Data Alternator Type Self excited 4 pole (1500rpm) single bearing, brushless
Output Voltage 3x415V
Voltage Regulation AVR±1.0% with 4% engine governing
Insulation Class H
Protection Rating IP23
Dimensions & Weights Length, A (mm) 1910 2220 2300 2770 3520 3900 4700 4900 5190 6000 12000
Width, B (mm) 860 970 1110 1430 1630 2320
Height, C (mm) 1120 1490 1590 1870 2020   2190   2600 2900
Dry weight (kg) 359 749 820 1080 1250 1340 1440 1630 2300 2350 2310 2360 3730 3800 4770  5060  10700  17000 

Derating: Given outputs are sea level ratings. Sets should be derated at 1% for every 100m above sea level, and 2% for every 5°C temperature above 20°C for naturally aspirated engines. For turbo charged engines, refer to supplier.